Industrial chillers are used in many industrial applications. So what determines the quality of industrial chillers?
First of all, the compressor as the heart of the industrial chiller is undoubtedly the most critical component. Although the domestic compressor industry has developed rapidly in recent years, the quality has also been greatly improved, but due to the limitations of domestic processing technology and the influence of national consciousness, Domestically produced compressors around the world will still be at a relatively low end. A good compressor not only has to be stable, but also has good energy efficiency.
Secondly, in addition to the compressor, the four most important components of the refrigeration system are the evaporator and the condenser. The evaporator and the condenser respectively act as heat absorption and heat release. The sufficient and suitable heat exchange capacity can fully exert the compression. The efficiency of the machine, if the heat exchange capacity of the condenser is insufficient, it will directly affect the refrigeration effect of the unit. In summer, the high pressure is high, and even the high-pressure over-standard causes the unit protection to stop. The heat exchange capacity of the evaporator is more important. Insufficient quantity will not only cause the unit to be inefficient, but the small amount will make the refrigerant not completely evaporate, and directly return to the compressor to cause liquid shock and damage the compressor. So, how can we ensure the quality of the evaporator and condenser? It is not difficult to find a professional manufacturer. The condenser and the evaporator adopt high-precision externally-threaded copper pipe precision numerical control high-strength sealing structure, which has good sealing performance and increases heat exchange capacity.
Finally, it is an expansion valve. In the industrial chiller refrigeration system, the expansion valve is both a flow regulating valve and a throttle valve in the refrigeration device. It is installed between the drying filter and the evaporator in the refrigeration device. The temperature sensor bag is wrapped at the outlet of the evaporator. Its main function is to reduce the pressure of the high-pressure normal temperature refrigerant liquid when flowing through the thermal expansion valve, and become a low-temperature low-pressure refrigerant wet steam (mostly liquid, a small part is steam) enters the evaporator and vaporizes in the evaporator. It absorbs heat and achieves the purpose of cooling and cooling. The configuration determines the quality of the industrial chiller, determines the reputation of the company, and chooses a good configuration to be the right customer, the right customer can trust you!
Find more info from
Application
Tel: +86 10 8178 9901 / 9902
Fax: +86 10 8178 7012 / 7013
Mob:+86 189 1133 7382
E-MAIL:sales@auwii.com
Add:4030, Building B, Hongfu International Innovation Center, Changping District, Beijing 102209