24-hour hot line:+86 189 1133 7382
GREEN  SAFETY  RELIABLE  EFFICIENT
sales@auwii.com
​​Committed to laboratory sample pretreatment and safety protection equipment R&D and manufacturing
NEWS AND TRENDS
Liquid chromatograph waste liquid collection and treatment plan
来源: | Author:AUWII | Time:2020-12-16 | 1860 Access | 分享到:
In April 2020, Aowei Instruments Green Laboratory Solution Products (solvent safety bottle caps, intubation type waste collection, funnel type waste collection) again contributed to the green environmental protection of major laboratories in China. Not long ago, a laboratory in Southwest China found us to solve the problem of liquid chromatograph waste.

In April 2020, Aowei Instruments Green Laboratory Solution Products (solvent safety bottle caps, intubation type waste collection, funnel type waste collection) again contributed to the green environmental protection of major laboratories in China. Not long ago, a laboratory in Southwest China found us to solve the problem of liquid chromatograph waste.

There is a liquid chromatograph in this teacher’s laboratory, and everyone knows that liquid chromatography is a type of separation and analysis technology. Its characteristic is that liquid is used as the mobile phase. The stationary phase can take many forms, such as paper, sheet and packed bed. The working principle is that the mobile phase flows through the injection valve through the infusion pump, is mixed with the sample solution, flows through the chromatographic column, is adsorbed and separated in the chromatographic column, and finally each component is converted into an electrical signal through a detector. The corresponding sample peak appears on the chromatographic workstation.

Because the teacher’s liquid chromatography processes a lot of mobile phases, like water phase: formic acid, acetic acid, perchloric acid, etc., organic phase: methanol, acetonitrile, dichloromethane, etc., and the main waste liquid collection of liquid chromatography is mobile The waste liquid produced after the phase and liquid samples are adsorbed and separated in the chromatographic column is usually collected by ordinary solvent bottles. The odor generated after the waste liquid volatilizes is very serious. The entire laboratory environment is very bad. When the teacher is online Contacted us immediately after seeing our products.

The teacher also chose our intubation type waste collection product, because this product has very rich interfaces, Φ4-8 inner diameter hose, Φ1.6-3.2 outer diameter hard pipe can be connected, and the bottle cap is optional Equipped with a variety of waste liquid filters can efficiently adsorb exhaust gas, the timing button can record the use time to remind replacement, the float level switch made of PVDF can also accurately detect the liquid level to prevent the waste liquid from overflowing.